LiveWire PowerCore 3300 Technical Specifications
Specification
|
Description
|
---|---|
Base
|
OEM Dell PowerEdge R7615 Server
|
Chassis
|
Chassis with up to 12 x 3.5" HDDs
|
Motherboard
|
OEM PowerEdge R7615 Motherboard
|
Processor
|
AMD EPYC 9354P 3.25 GHz, 32C/64T
|
Memory
|
256 GB or RAM
32GB RDIMM, 4800MT/s, Dual Rank (8)
|
RAID/Internal Storage Controllers
|
PERC H755 Adapter, Low Profile
|
Hard Drive
|
960 GB BOSS M.2 Drives (2)
20 TB Hard Drive SAS 12 Gbps 7.2 K 512e 3.5 in Hot-Plug (12)
|
Network Adapters
|
Broadcom 5720 Dual Port 1Gbe LOM
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0
|
Fans
|
Performance Fans (6)
|
Power Supply
|
Dual, Hot-Plug, Power Supply, 2400W MM (100-240 Vac), Redundant (1+1)
|
Power Cords
|
C13, 3 M, 125 V, 15 A (2)
|
PCIe Riser
|
Riser Config 3
- 2 x 16 FH (Gen5)
- 2 x 8 FH
- 2 x 16 LP, Half Length
|
Embedded Systems Management
|
iDRAC9, Enterprise
|
Quick Sync
|
None
|
Rack Rails
|
ReadyRails Sliding Rails Without Cable Management Arm
|
PSU Specifications:
PSU
Class
Heat Dissipation (Maximum)
Frequency
Voltage
High Line 200 V 240 V
Low Line 100-140 V
Current
|
2400 W mixed mode
Platinum
9000
50/60
2400 W
1400
N/A
N/A
|
Temperature Specifications ASHRAE A2:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes < = 900 m (< = 2953 ft)
|
10–35°C (50–95°F) with no direct sunlight on the equipment
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
|
Temperature Specifications ASHRAE A3:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes < = 900 m (< = 2953 ft)
|
5–40°C (41–104°F) with no direct sunlight on the equipment
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
|
Temperature Specifications ASHRAE A4:
|
|
Allowable continuous operations
|
|
Temperature range for altitudes < = 900 m (< = 2953 ft)
|
5–45°C (41–113°F) with no direct sunlight on the equipment
|
Humidity percent range (non-condensing at all times)
|
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
|
Operational altitude de-rating
|
Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
|
Relative Humidity Specifications:
|
|
Operating
|
10% to 80% relative humidity with 29°C (84.2°F) maximum dew point.
|
Storage
|
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point. Non-condensing at all times.
|
Maximum Vibration Specifications:
|
|
Operating
|
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations)
|
Storage
|
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
|
Maximum Shock Pulse Specifications:
|
|
Operating
|
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms
|
Storage
|
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms
|